Conductive transmitters and controllers for conductivity

JUMO offers you a choice of different, high-quality transmitters and controllers for conductive conductivity measurement in liquids (e.g. compact and separate design type, IO-Link, or JUMO digiLine – the intelligent, bus-compatible connection system).

  • Product selection guide

Conductive transmitters cand controllers for conductivity

Filter
1
Hits: 14
JUMO AQUIS touch S - Modular multichannel measuring device (liquid analysis)

JUMO AQUIS touch S

Modular multichannel measuring device (liquid analysis) Basic type: 202581
The product is intended as a platform for measuring, controlling, recording, and displaying the pH value/redox, electrolytic conductivity, high-purified water resistance, temperature, disinfection measurands (such as free chlorine, total chlorine, chlorine dioxide, ozone, hydrogen peroxide, and peracetic acid), and the totalized flow rate.
  • Wall-surface-mounted housing
  • 4 analysis sensors and 21 measuring signals
  • P, PI, PD, and PID behavior
JUMO AQUIS touch P - Modular multichannel measuring device (liquid analysis)

JUMO AQUIS touch P

Modular multichannel measuring device (liquid analysis) Basic type: 202580
The product is intended as a platform for measuring, controlling, recording, and displaying the pH value/redox, electrolytic conductivity, high-purified water resistance, temperature, disinfection measurands (such as free chlorine, total chlorine, chlorine dioxide, ozone, hydrogen peroxide, and peracetic acid), and the totalized flow rate.
  • Panel built-in device
  • 2 analysis sensors and 15 measuring signals
  • P, PI, PD, and PID behavior
JUMO AQUIS 500 CR - Transmitter and controller for conductivity

JUMO AQUIS 500 CR

Transmitter and controller for conductivity Basic type: 202565
The product controls the electrolytic conductivity, the specific electrical resistivity, or the TDS value. Conductive two-electrode measuring cells as well as four-electrode measuring cells can be connected to the device.
  • For conductivity, temperature, TDS
  • LCD graphic display
  • Calibration option
JUMO ecoTRANS Lf 01/02 - Transmitter and switching device for conductivity

JUMO ecoTRANS Lf 01/02

Transmitter and switching device for conductivity Basic type: 202731
The product measures the conductivity of liquids in conjunction with conductivity measuring cells. It is designed for use in general water technology.
  • For conductive conductivity sensors
  • 1 analog output (Lf 01)
  • 1 relay output (Lf 02)
JUMO ecoTRANS Lf 03 - Transmitter and switching device for conductivity

JUMO ecoTRANS Lf 03

Transmitter and switching device for conductivity Basic type: 202732
The product measures the conductivity or the resistance of liquids in conjunction with conductive conductivity measuring cells. Typical application areas are plants for fresh water monitoring and water treatment, reverse osmosis plants, etc.
  • For conductive conductivity sensors
  • 2 actual value outputs, 1 switching output
  • Calibration timer
JUMO digiLine CR HT20 - Head transmitter with conductive two-electrode conductivity sensor type PVC

JUMO digiLine CR HT20

Head transmitter with conductive two-electrode conductivity sensor type PVC Basic type: 202764
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 0.1 µS/cm to 15 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR HT30 - Head transmitter with conductive two-electrode conductivity sensor type VA

JUMO digiLine CR HT30

Head transmitter with conductive two-electrode conductivity sensor type VA Basic type: 202765
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 0.05 µS/cm to 1 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR HT40 - Head transmitter with conductive two-electrode conductivity sensor type SL

JUMO digiLine CR HT40

Head transmitter with conductive two-electrode conductivity sensor type SL Basic type: 202766
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 0.05 µS/cm to 1 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR HT50 - Head transmitter with conductive two-electrode conductivity sensor type PK

JUMO digiLine CR HT50

Head transmitter with conductive two-electrode conductivity sensor type PK Basic type: 202767
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 0.05 µS/cm to 1 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR HT60 - Head transmitter with conductive two-electrode conductivity sensor type GT

JUMO digiLine CR HT60

Head transmitter with conductive two-electrode conductivity sensor type GT Basic type: 202768
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 10 µS/cm to 15 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR HT70 - Head transmitter with conductive four-electrode conductivity sensor type 4P

JUMO digiLine CR HT70

Head transmitter with conductive four-electrode conductivity sensor type 4P Basic type: 202769
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 1 µS/cm to 600 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR HT10 - Head transmitter with conductive two-electrode conductivity sensor type EC

JUMO digiLine CR HT10

Head transmitter with conductive two-electrode conductivity sensor type EC Basic type: 202763
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 0.1 µS/cm to 100 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR ST10 - Transmitter for separate conductive conductivity sensor

JUMO digiLine CR ST10

Transmitter for separate conductive conductivity sensor Basic type: 202762
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. In addition to the JUMO digiLine interface, system integration can now also take place via an IO-Link interface.
  • Separate design type for conductive sensors
  • Measuring range: 0.05 µS/cm to 600 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO dTRANS CR 02 - Compact multichannel transmitters and controllers for conductivity

JUMO dTRANS CR 02

Compact multichannel transmitters and controllers for conductivity Basic type: 202552
The product controls and records the electrolytic conductivity, the specific electrical resistivity, or the TDS value. Both conductive two-electrode and four-electrode measuring cells can be connected as well as a pulse generator for flow measurement.
  • For conductive conductivity, temperature
  • RS422/485 interface
  • Surface or control cabinet mounting

item items, maximum number of items reached