• Product selection guide

Thermocouple

Filter
1
Hits: 13
Welding protective sleeves - For thermocouples and RTD temperature probes

Welding protective sleeves

For thermocouples and RTD temperature probes Basic type: 909712
Welding protective sleeves are used for installing thermocouples and RTD temperature probes when replacement without draining the system and/or pressure resistance is required Pressure stability is temperature dependent and specified in the data sheet.
  • Operating temperatures up to 450 °C
  • Protection tube made out of steel or stainless steel
  • Insertion length 250 mm
Terminal heads - For thermocouples and RTD temperature probes

Terminal heads

For thermocouples and RTD temperature probes Basic type: 909715
DIN EN 50446 defines the terminal head design types A and B, which differ in size and also slightly in their shape. Aluminum or plastic is used, depending on the application. These design types are suitable for the installation of a two-wire transmitter.
  • Temp.: -40 to +100 / -30 to +130 °C
  • Form A, B, BBK, BUZ, BUZH, J
  • Protection type IP54 and IP65
Connection socket - For thermocouples and RTD temperature probes

Connection socket

For thermocouples and RTD temperature probes Basic type: 909717
Connection sockets with 2, 4, or 6 connections are available to suit the different terminal heads for thermocouples and RTD temperature probes.
  • 2, 4, or 6 connections
  • For form A, B, BBK, BUZ, BUZH, J
  • Fasten by locking into place or using screws
Measuring inserts for screw-in thermocouples - With terminal head form B

Measuring inserts for screw-in thermocouples

With terminal head form B Basic type: 909742
The measuring inserts for screw-in thermocouples with a form B terminal head are used as replacements. They are suitable for screw-in thermocouples according to data sheet 901020. Sheath measuring inserts are available for measuring insert lengths as of 800 mm.
  • Temp.: -200 to +1150 °C
  • Measuring insert length 315 to 800 mm
  • Measuring insert K or L
Thermocouples - According to DIN 43 732

Thermocouples

According to DIN 43 732 Basic type: 909744
Thermocouples are designed as replacement elements for thermocouples according to DIN 43733. Alternatively, for special applications the thermocouples can be used to measure temperature directly.
  • Temp.: -200 to +1600 °C
  • Thermocouples type L, K, S, or B
  • Length: 220 to 2040 mm
Plug connections - For thermocouples

Plug connections

For thermocouples Basic type: 909760
To prevent thermoelectric voltage in the connection between the thermocouple and compensating cable, the contacts for the plug connections and the thermocouple should be made from the same material. Accordingly, non-thermoelectric voltage plug connections with different contacts are available.
  • Temp.: -60 to +200 °C
  • Type of element "J", "K", and "S"
  • Plastic
Compensating cables/thermal cables - For the electrical connection to thermocouples

Compensating cables/thermal cables

For the electrical connection to thermocouples Basic type: 909735
The temperature measurement using thermocouples requires the temperature of the cold junction to be measured in addition to the thermoelectric voltage. The cold junction temperature is acquired at the connection terminals of the evaluation electronics.
  • Temp.: -50 to +350 °C
  • For dry and humid locations
  • DIN EN 60584 and DIN 43714
Bayonet fasteners - For push-in RTD temperature probes and push-in thermocouples

Bayonet fasteners

For push-in RTD temperature probes and push-in thermocouples Basic type: 909754
Bayonet fasteners allow temperature probes to be quickly locked and unlocked at the installation location. The option to change the insertion length is also an advantage. Versions with different threads and diameters can be combined using corresponding socket diameters.
  • Temperature up to 600 °C
  • Different diameters
  • Brass 2.0401.20, nickel-plated
Bayonet sockets - For push-in RTD temperature probes and push-in thermocouples

Bayonet sockets

For push-in RTD temperature probes and push-in thermocouples Basic type: 909755
Bayonet fasteners allow temperature probes to be quickly locked and unlocked at the installation location The option to change the insertion length is also an advantage. Versions with different threads and diameters can be combined using corresponding socket diameters.
  • Temperature up to 600 °C
  • Different threads
  • Stainless steel, 1.4305 / brass, 2.0401.20
Compression fittings - For protection tubes according to DIN 43763, mineral-insulated RTD temperature probes and mineral-insulated thermocouples

Compression fittings

For protection tubes according to DIN 43763, mineral-insulated RTD temperature probes and mineral-insulated thermocouples Basic type: 909750
Using compression fittings, mounting and removing temperature probes is easy. Another advantage is the variable insertion lengths. Different materials and threads can be selected for the combination with different protection tube diameters.
  • Temperatures up to 600 °C
  • Different diameters
  • Steel, stainless steel 1.4571 / 1.47305
Flanges - For RTD temperature probes and thermocouples

Flanges

For RTD temperature probes and thermocouples Basic type: 909752
Temperature probes can be easily mounted and removed with stop flanges made of different materials and for different protection tube diameters. The variable positioning of the insertion length is also an advantage. A counter flange can be used to seal the measuring point up to 1 bar.
  • Various protection tube diameters
  • Gray cast iron and sheet flanges made of steel
  • Temperature up to 600 °C
Screw-in thermowells - For thermocouples and RTD temperature probes
H2 Signet

Screw-in thermowells

For thermocouples and RTD temperature probes Basic type: 909710
Screw-in thermowells are used for installing thermocouples and RTD temperature probes when replacement without draining the system and/or pressure resistance is required. Pressure stability is temperature dependent and specified in the data sheet.
  • Operating temperatures up to 400 °C
  • Protection tube made out of steel or stainless steel
  • Insertion length 260 mm
JUMO Device App - Mobile access to JUMO devices

JUMO Device App

Mobile access to JUMO devices Basic type: 709771
The JUMO Device App provides the user with mobile access to their process data at all times. All current process values as well as the alarm and event list from selected JUMO devices which are networked via Ethernet can be viewed in text form.
  • IP address/DNS name
  • Retrieval of event/alarm lists
  • Scan function for device search

item items, maximum number of items reached